Back to Contents Page

The Dell PowerVault 660F Storage System

Dell OpenManage™ Array Manager 3.4

  PowerVault 660F Storage System Description

  Array Manager Storage Model

  Dell PowerVault 660F Storage System Configuration Overview

  Dell PowerVault 660F Storage System Commands and Procedures Summary

  Array Group Commands

  Disk Group Commands

  Virtual Disk Commands

  Array Disk Commands

  Fibre Channel RAID Controller Commands

  Change Low Threshold

  Subsystem Commands

  Enclosure Management Overview and Commands

  RAID Policies

  NetWare Support for the PowerVault 660F

  How the Battery Backup Unit Works

This chapter describes how to configure and manage arrays with the Dell PowerVault™ 660F Storage System.

Note A Dell PowerVault 660F Storage System must be managed by only one Array Manager managed system. Having more than one Array Manager managed system enabled to manage the same Dell PowerVault 660F Storage System will result in improper function in Array Manager. See Adding and Removing Fibre Channel RAID and Enclosure Management in the Array Manager Utilities chapter for details.

PowerVault 660F Storage System Description

The Dell PowerVault 660F Storage System is a high-performance Fibre Channel host to Fibre Channel disk array controller. It provides one external Fibre host channel and two internal fibre drive channels conforming to Fibre Channel standards. The logical protocol used for both host and disk communications is 100 MB/s Fibre Channel Protocol (FCP) SCSI over fibre. The storage system provides Fibre Channel host performance and fault-tolerant RAID disk operations for Fibre Channel disk environments. The Fibre Channel RAID controllers used in the storage system are intelligent, caching controllers that support concatenation and RAID levels 0, 1, 3, 5, and 0+1. The storage system can be used in either a dedicated direct-attach configuration, or it can allow multiple hosts in a Storage Area NetWork (SAN) to access the array of physical disk drives (array disks), which can be configured as one or more virtual storage devices (virtual disks).

The Dell PowerVault 660F storage system also provides continuous access to data in the event of a single controller failure. This capability comes with a redundant controller system, using two controllers that share access to the same disk array. In the event of a controller failure, controller operations are assumed by the surviving controller through a failover process. The failed controller can then be removed and replaced while the system is online. The new controller resumes processing array operations in a failback process. During failover and failback, write cache coherency is maintained with the array disks.

The controller supports a battery backup unit (BBU) for maintaining memory content in case of an AC power failure. The principal purpose of the BBU is to provide cache fault tolerance during a power glitch; however, the BBU is capable of sustaining memory content for hours at a time, depending on the type and size of the memory. The fault management features are based on the SCSI-3 Enclosure Services (SES) device interface.

The following features are available on the Dell PowerVault 660F Storage System:

Supported RAID Levels

The Dell PowerVault 660F Storage System supports the following RAID levels:

Note With RAID-3 the parity is usually dedicated to a single array disk. The PowerVault 660F storage system, however, implements RAID-3 in the same manner as RAID-5, with distributed parity across multiple disks.

Supported RAID Levels 

RAID
Level


Description

# of Drives
Min. Max.

Fault
Tolerant

Concatenation

Storing data on a single array disk

1

1

No

0

Block striping is provided, which yields higher performance than is possible with individual disk drives. No redundancy is provided.

2

16

No

1

Disk drives are paired and mirrored. All data is 100% duplicated on an equivalent disk drive.

2

2

Yes

3 and 5

Data is striped across several physical disk drives. Parity protection is used for data redundancy.

3

16

Yes

0+1

Combination of RAID levels 0 and 1. Data is striped across disks with mirrors of the stripe chunks on adjacent disks. This can be configured to have an odd or even number of disks.

3

16

Yes

Maximum Virtual Disks per Storage System

You can create a maximum of 32 virtual disks on a Dell PowerVault 660F Storage System.

Conservative Cache Mode

Conservative Cache mode is a feature of the Dell PowerVault 660F Storage System. It is an operating mode in which virtual disks configured with the write-back caching policy are treated as though they were configured for write-through operation and the cache is flushed. Conservative Cache mode is entered to provide a higher level of data protection after a critical system component has failed. When the condition forcing Conservative Cache mode is resolved, the cache policies on the system drives are changed back to their original settings.

Conditions that cause Conservative Cache execution are:

For information on how to change the conservative cache mode setting, see Advanced Fibre Channel RAID Controller Options. By default, conservative cache mode is enabled.

Understanding Virtual Disk Initialization

Initializing a virtual disk makes the disk space on the member array disks available to the operating system for future read and write operations. Array Manager provides two methods for initializing a virtual disk:

Foreground and Background Initialization

When using foreground initialization, the system cannot perform read and write operations to the virtual disk being initialized. Foreground initialization also writes zeroes (0) to the disks being initialized, effectively destroying any data or redundancy information previously residing on those disks.

When using background initialization, the initialization is performed as a background process which enables the system to perform read and write operations to the virtual disk as it is being initialized.

In contrast to foreground initialization, background initialization does not zero out the existing data on the disks. Instead, background initialization only sets the redundancy or parity data on the virtual disk without changing the user data. This means that for a newly created virtual disk that was background initialized, the data region of the virtual disk will contain any data that existed on the array disks before the virtual disk was created. In order to clear the user data regions in an initialization, you must use the foreground initialize function instead.

Background initialization can only be used with virtual disks configured as redundant RAID levels.

Background initialization is one of the Advanced Fibre Channel RAID Controller Options. By default, background initialization is enabled.

How the Controller Implements Background Initialization

As long as the Autostart Background Init option in the Advanced Fibre Channel RAID Controller Options is set to the default setting of enabled, then the system automatically performs a background initialization on any uninitialized virtual disks when a write operation is performed on the virtual disk.

Operations that Suspend Background Initialization

The following operations cause the background initialization process to be suspended:

System Performance Impacts of Background Initialization

Background initialization does impact system performance. You may notice that read and write operations to virtual disks contained in the same disk group as the virtual disk being initialized are slower when performing a background initialization.

Once the background initialization has started, the system dedicates a certain percentage of the processor bandwidth to the background initialization, regardless of what other operations are being performed on the controller. This percentage of the processor bandwidth will continue to be dedicated to the background initialization until the initialization either completes or is paused.

The impact that background initialization has to system performance is based on the rebuild rate. You can change the rebuild rate by using the Expert Fibre Channel RAID Controller Options.

Background Initialization and a Disabled Partner Controller

If the partner controller is disabled while a background initialization is in process, the background initialization will experience a short interruption and then continue processing. The disabled controller (or its replacement) are held in reset until the background initialization completes.

You must wait for the background initialization to complete before initiating the Enable Partner command. When the Enable Partner command is initiated, the partner controller fails back.

Events Generated by Background Initialization

The following events are generated by a background initialization and displayed in the Array Manager event log:


Array Manager Storage Model

Working with these controllers requires an understanding of the Array Manager storage model, which represents the Array Manager storage objects in an object hierarchy. Each object has a set of attributes and operations associated with it. Attributes describe the properties of the object, and operations allow you to create new objects and modify existing object attributes. See The Array Manager Storage Model section in the Storage Management Concepts chapter for more information about the Array Manager storage model.

Operations that are inactive (dimmed) in the console are not supported or not available at that time. To view attributes or to perform operations, right-click a given storage object. A context menu will appear with a list of commands available, including a Properties command.

Because the controllers in each subsystem support different features, the objects in the expanded tree view may vary for each subsystem. For example, the PV660F subsystem does not support tape devices or CDROMs. Therefore, the PV660F subsystem does not have a Tape or CDROM object in the tree view.


Dell PowerVault 660F Storage System Configuration Overview

This section summarizes the steps for configuring the storage attached to a Dell PowerVault 660F Storage System.

  1. Determine requirements for disk groups, virtual disks, and hot spares, including the storage capacity and RAID type for each virtual disk. Make sure the requirements for operating system partitions, fault tolerance, and total capacity are considered during this determination. Note that hot spares are used both for recovery from disk failure and for future capacity expansion.

  2. Identify requirements for future capacity expansion. Note that if a virtual disk is to be expanded, it must be the only virtual disk in its disk group. Keep this in mind when determining whether to create one or many virtual disks within a disk group.

  3. Create required disk groups and virtual disks. Note the following considerations:

  4. Assign one or more hot spares to enable auto-rebuild in the event of drive failure within a fault-tolerant virtual disk.

  5. On a Windows system, if the PowerVault 660F storage system is part of a SAN, you must first assign the virtual disk to a server by using the Dell OpenManage™ Storage Consolidation software before a server can use the virtual disk. Once assigned to a server (or if configured in a "direct-attach" hardware configuration) you must perform a rescan (or reboot the server in Windows NT) in order to access the virtual disk.

  6. Create and format operating system partitions to complete the configuration. See the Disk Management and Volume Management chapters for details on how to perform this step with Windows NT or Windows 2000.


Dell PowerVault 660F Storage System Commands and Procedures Summary

The remainder of this chapter provides detailed information on the Dell PowerVault 660F Storage System commands and procedures and has the following main topics:


Array Group Commands

An array group contains disk groups of array disks that are controlled by a particular storage system. Array disks are numbered according to the enclosure number and the enclosure slot number. For example, Array Disk 1:7 indicates that the disk belongs to the first enclosure and resides in slot 7 of the enclosure. The enclosure slot numbers are accessible on the exterior of the enclosure allowing for easy identification of a particular array disk.

Because the Dell PowerVault 660F Storage System can support 112 array disks in a single array group, array disks are further divided into disk groups with up to 16 array disks each. You create one or more virtual disks from a disk group.

You can perform the following operations from the Array Group context menu:

To bring up an array group's context menu, right-click the array group object in the tree view.

Create Disk Group

Use this function to create a disk group of available physical array disks. The disk group of array disks will be used to create virtual disks. You can have up to 16 array disks per disk group. Before you create a disk group, consider the following items:

To Create a Disk Group
  1. Right-click an array group.

  2. Click Create Disk Group. The Create Disk Group dialog box appears.

  3. Select one or more array disks from the Available Array Disks list. Click Add Disk to add the disks to the Add Array Disks list. Continue adding disks as required by your configuration.

  4. Disks can be removed from the Add Array Disks list by selecting the specific disk and clicking on Remove Disk, or remove all disks from the Add Array Disks list by clicking on Remove All.

  5. Verify that the Add Array Disks list contains the appropriate disks. Click OK to invoke the changes. (Click Cancel to discontinue the operation.)

Add Spares

Use this function to create a global hot spare disk. A global hot spare disk is an array disk that will be used to rebuild disk groups containing redundant virtual disks. A hot spare is also required before you can use the Expand Capacity or Add Virtual Disk commands.

Caution Only disk groups that don't contain non-redundant virtual disks are eligible to have a global hot spare rebuild a failed array disk. Disk groups containing concatenated virtual disks or RAID 0 virtual disks will not have a failed array disk rebuilt with a global hot spare disk.
  1. Right-click an array group.

  2. Click Add Spares. The Add Spares dialog box appears.

  3. Select one or more array disks from the Available Array Disks list. Click Add Disk to add the disks to the Add Array Disks list. Continue adding spare disks as required by your configuration.

  4. Disks can be removed from the Add Array Disks list by selecting the specific disk and clicking on Remove Disk, or remove all disks from the Add Array Disks list by clicking on Remove All.

  5. Verify that the Add Array Disks list contains the appropriate disks. Click OK to make the changes. (Click Cancel to discontinue the operation.)

A specific array disk with Ready status can also be made a global hot spare by right clicking on it and selecting Make global hotspare.

Note If multiple array disks that are different sizes are configured as global hot spares, a rebuild will choose the array disk that best fits the array disk that failed.

Reset Configuration

Use this function to delete all configuration information on the Fibre Channel RAID controller, so you can create a fresh configuration.

Caution Resetting a configuration permanently destroys all data on the Fibre Channel RAID controller and array disks. This operation is not recoverable.
Note It is strongly recommended that you first delete all the volumes (and unassign the virtual disks using Dell OpenManage Storage Consolidation if the array is configured in a Storage Area Network) before performing a Reset Configuration.
  1. Right-click an array group.

  2. Click Reset Configuration. A warning/confirmation dialog box appears warning that all virtual disks and data will be lost. The user is asked to confirm this operation.

  3. Click Yes to continue. (Click No to exit the function.)

Edit RAID Policy

Use this function to create, edit, or delete RAID policies.

To Create a New RAID Policy
  1. Right-click a disk group.

  2. Click Edit RAID Policy. The RAID Policy Editor screen appears.

  3. Click New Policy. An empty detailed RAID Policy Editor screen appears.

  4. Click Add Disk. A disk with empty attribute fields appears on the screen.

  5. Edit the fields by typing the appropriate information, or double-click in the field for a context menu of possible settings.

Note When creating multiple disks in a RAID Policy, keep in mind the restrictions of RAID levels and the number of array disks needed. For example, having a RAID policy containing a RAID 1 and RAID 5 isn't possible since RAID 1 is only valid with 2 array disks, and RAID 5 requires at least 3 array disks.
  1. Add more disks as required for your configuration.

The last disk in the list can be removed from the configuration by clicking Remove Disk.

  1. Enter a name in the Policy Name field.

  2. When all settings are correct, click OK to return to the main RAID Policy Editor screen. (Click Cancel to discontinue the operation.)

  3. Click OK to save the configuration. (Click Cancel to discontinue the operation.)

To Edit an Existing RAID Policy
  1. Right-click a disk group.

  2. Click Edit RAID Policy. The RAID Policy Editor screen appears.

  3. Select the RAID policy you wish to modify.

  4. Click Modify Policy. A detailed RAID Policy Editor screen appears showing the attributes of the selected RAID policy.

  5. Edit the fields by typing the appropriate information, or double-click in the field for a context menu of possible settings.

  6. Add or delete disks as required by your configuration.

  7. When all settings are correct, click OK to return to the main RAID Policy Editor screen. (Click Cancel to discontinue the operation.)

  8. Click OK to save the configuration. (Click Cancel to discontinue the operation.)

To Delete a RAID Policy
  1. Right-click a disk group.

  2. Click Edit RAID Policy. The RAID Policy Editor screen appears.

  3. Select the RAID policy you wish to delete.

  4. Click Delete Policy.

  5. Click OK to save the configuration. (Click Cancel to discontinue the operation.)

Array Group Properties

The Properties command for a selected array group displays the following information:

Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Disk Group Commands

You can perform the following operations from the Disk Group context menu:

To bring up a disk group's context menu, right-click the disk group object in the tree view.

Create Virtual Disk

Creating virtual disks allows you to choose from a variety of RAID configurations to make the best use of your array disk storage. You must create a disk group before creating a virtual disk, because the array disks for a virtual disk are chosen by a disk group. See Create Disk Group in this chapter for details.

The Dell PowerVault 660F Storage System supports the following RAID configurations: concatenation, RAID-0, RAID-1, RAID-3, RAID-5, and RAID-0+1. For more information about RAID configurations, see Choosing RAID Levels in the Storage Management Concepts chapter.

Note When you create virtual disks, you may want to consider how virtual disks must be deleted. Because of hardware constraints, virtual disks must be deleted in reverse order of their creation. In other words, you must delete the most recently created virtual disk first and continue to delete in reverse order.
  1. Right-click a disk group. For information on creating a disk group, see Create Disk Group.

  2. Select Create Virtual Disk from the Task pull-down menu. The Welcome to the Create Virtual Disk Wizard screen appears.

  3. Read the welcome screen and click Next to continue. (Click Cancel to discontinue the operation.) The Select Virtual Disk Type screen appears.

  4. Select the Type, Size, Stripe Size (only settable for the storage system's first virtual disk), and Write Policy for the virtual disk.

Supported virtual disk types or RAID levels are available in the drop-down menu of the Type field. The choices shown in the drop-down menu depends on the number of array disks in the disk group.

Note When creating virtual disks in a disk group, use non-redundant RAID levels (such as concatenated or RAID 0) only when the disk group will not need hot-spare disk replacement. If a disk group contains at least one non-redundant virtual disk, any failed array disks in the disk group cannot be rebuilt with a hot-spare array disk.

The actual size of the virtual disk may be larger than what you specify. This is because the virtual disk size is rounded up according to the RAID level and the number of array disks in the disk group. For more information on how the actual disk size is determined, see Virtual Disk Size.

The stripe size is selectable only on the first virtual disk created. Supported stripe size values are available in the drop-down menu of the Stripe Size field. When you create additional virtual disks, the stripe size setting is inactive (dimmed) because there can be only one stripe size for all virtual disks on the same Dell PowerVault 660F storage system.

The Write Policy toggles between Write Cache Enabled and Write Cache Disabled. When write cache is enabled, the Fibre Channel RAID controller returns a completion status to the host as soon as the cache memory receives the data. The array disk receives the data at a more appropriate time. When write cache is disabled, the controller writes data to the array disk before returning completion status to the host.

  1. When the virtual disk attributes are set appropriately, click Next to continue. (Click Back to return to the previous screen. Click Cancel to discontinue the operation.) The Completing the Create Virtual Disk Wizard screen appears.

Note Initializing the new virtual disk is strongly recommended and may take approximately one hour to complete for foreground initialization, depending on the size of the virtual disk. Multiple simultaneous disk foreground initializations are supported, but having more than eight virtual disk initializations running at the same time can slow down the response time of commands from Array Manager to that PowerVault 660F fibre channel array. Array Manager does not allow initialization to immediately occur after virtual disk creation if eight virtual disk initializations are already ongoing. You will have to later manually start an initialization when one or more of the current initializations are finished, or you can plan to use background initialization to have the virtual disks initialized.
  1. Check the Initialize Disk option if you want to perform a foreground initialization on the new virtual disk immediately, and click Finish to create the virtual disk as determined in the previous steps. (Click Back to return to the previous screen. Click Cancel to discontinue the operation.)

Note If you want, initialization can be performed later by choosing Initialize or Background Initialize (if available) from the Virtual Disk context menu. Also, if the Autostart Background Init controller option is set, the virtual disk is automatically queued up for background initialization when it is created. The Background Initialize controller option is only available when using PowerVault 660F controller firmware 7.7 or later.
Note Starting a foreground initialization (by checking the Initialize Disk option) will suspend any active background initializations on another virtual disk. The background initialization will continue once all foreground initializations are either completed or canceled.

If this is the first virtual disk created, a dialog box notifying the user that the controller needs to reset appears. The reset operation may take more than 30 seconds to complete.

  1. After foreground initialization completes (or background initialization has started to run), do one of the following:

  1. Add a disk signature to the virtual disk.

For instructions on writing a disk signature, see the section Write a Disk Signature in the Disk Management chapter.

Your virtual disk is now ready to be used by the server.

Virtual Disk Size

Because the PowerVault 660F storage system rounds up the size of the virtual disk, the actual size of the virtual disk may be larger than what you specified when creating the virtual disk. The method for rounding up the virtual disk size varies depending on the RAID level and the number of array disks in the disk group. The following table indicates how the virtual disk size is rounded up.

Virtual Disk Size on a PowerVault 660F Storage System

RAID Level

Method for Determining Virtual Disk Size

RAID 0 and Concatenated

2 MB x (number of array disks in the disk group)

RAID 1 and RAID 0 + 1

1 MB x (number of array disks in the disk group)

RAID 3 and RAID 5

2 MB x (number of array disks in the disk group - 1)

Apply RAID Policy

Use this function to apply RAID policies to create virtual disks.

Note If you use this method, all your virtual disks will be in one disk group. You will not be able to use the Expand Capacity command to add array disks in the future if the policy contains more than one virtual disk.
  1. Right-click a disk group.

  2. Click Apply RAID Policy. The Welcome to the RAID Policy Wizard screen appears.

  3. Read the welcome screen and click Next to continue. (Click Cancel to discontinue the operation.) The Select RAID Policy screen appears.

  4. Use the RAID Policy Browser to select a RAID policy to apply to the array disk group. Check the disk(s) for which this RAID policy is to be applied. Changes can be made to this policy's settings by double-clicking on any of the fields. These changes will be applied "on the fly" without editing or creating a new RAID policy. Click Revert to default to revert to the existing policy's default settings.

Note When changing the RAID level for disks in a RAID Policy, keep in mind the restrictions that apply to the number of array disks required for a particular RAID level. For more information on these restrictions, see Supported RAID Levels. If you select a RAID level that is inappropriate for the number of available array disks, an error message displays.
  1. When the RAID policies are set appropriately, click Next to continue. (Click Back to return to the previous screen. Click Cancel to discontinue the operation.) The Completing the RAID Policy Wizard screen appears.

Note Initializing the new virtual disk is strongly recommended and may take one hour or longer to complete for foreground initialization, depending on the size of the virtual disk. Multiple simultaneous disk foreground initializations are supported, but having more than eight virtual disk initializations running at the same time can slow down the response time of commands from Array Manager to the PowerVault 660F fibre channel array. Array Manager will not allow initialization to immediately occur after virtual disk creation if eight virtual disk initializations are already ongoing. You will have to later manually start a initialization when one or more of the current initializations are finished.
  1. Check the Initialize Disk option if you want to immediately perform a foreground initialization on the new virtual disk, and click Finish to create the virtual disk as determined by the RAID policy chosen. (Click Back to return to the previous screen. Click Cancel to discontinue the operation.)

Note If you wish, initialization can be performed later by choosing Initialize or Background Initialize from the Virtual Disk context menu. Also, if the Autostart Background Init controller option is set, the virtual disk is automatically queued up for background initialization when it is created.
Note Starting a foreground initialization (by checking the Initialize Disk option) will suspend any active background initialization occurring on another virtual disk. The background initialization will continue once all foreground initializations are either completed or canceled.

If this is the first virtual disk created, a dialog box notifying the user that the controller needs to reset appears. The reset operation may take more than 30 seconds to complete.

  1. After the foreground initialization completes (or background initialization starts), do the following:

  1. Add a disk signature to the virtual disk.

For instructions on writing a disk signature, see the section Write a Disk Signature in the Disk Management chapter.

After applying the RAID policy to a virtual disk, you may note that the size of the virtual disk is larger than the size you specified when creating the virtual disk. This is because the virtual disk size is rounded up according to the RAID level and the number of array disks in the disk group. For more information on how the actual disk size is determined, see Virtual Disk Size.

Expand Capacity

Use this function to increase the capacity of an existing disk group while the storage system is online. The Expand Capacity command appends the added array disk's capacity to the existing virtual disk in the disk group. In contrast, the Add Virtual Disk command expands a disk group by adding a new virtual disk, using the existing and added array disks.

The Expand Capacity command is not available (menu option is dimmed) unless the following conditions are met:

Note that the following considerations apply when using the Expand Capacity command:

Use the following procedure to increase the capacity of an existing virtual disk in a disk group:

  1. Right-click a disk group containing the virtual disk to be expanded.

  2. Click Expand Capacity. The Expand Capacity dialog box appears.

  3. Select one or more array disks from the Available Array Disks list. Click Add Disk to add the disks to the Add Array Disks list. Continue adding disks until you want to stop or you reach the 16 array disk limit.

Array disks can be removed from the Add Array Disks list by selecting the specific disk and clicking on Remove Disk, or remove all disks from the Add Array Disks list by clicking on Remove All.

  1. Verify that the Add Array Disks list contains the appropriate disks. Click OK to make the changes. (Click Cancel to discontinue the operation.)

A temporary disk group appears that contains the selected array disks. This disk group remains until the Expand Capacity procedure is completed. When the procedure is finished, the temporary disk group will be removed and the selected array disks are displayed under the disk group that contains the virtual disk that has been expanded.

The Expand Capacity process may take hours to complete, depending on the number of disks involved and their capacity.

  1. After the Expand Capacity process has completed, you MUST enable the partner controller to re-establish controller redundancy.

See the Enable Partner commands.

Caution No rebuilds of redundant virtual disks will take place until after the Expand Capacity operation is completed and the partner controller is enabled.
  1. If the virtual disk is on a Windows NT server, you must first reboot to use the additional free space. For a Windows 2000 or Windows Server 2003 server, you must perform a console rescan for the server to recognize the additional space.

  2. You are now ready to either expand existing file systems on the free space, or put a format and a file system on the free space.

Refer to Working with Dynamic Volumes in the Volume Management chapter.

Add Virtual Disk

This function allows additional array disks to be added to a disk group, using the additional space of the added array disks as a new virtual disk. Existing virtual disks in the disk group are restriped across the new set of array disks.

The Add Virtual Disk command is not available (menu option is dimmed) unless the following conditions are met:

Note Starting an Add Virtual Disk suspends any background initialization occurring on another virtual disk. The background initialization will continue once the Add Virtual Disk is completed or canceled.

The Add Virtual Disk adds a new virtual disk, using the existing array disks.

  1. Right-click a disk group.

  2. Click Add Virtual Disk. The Welcome to the Add Virtual Disk Wizard screen appears.

  3. Read the welcome screen and click Next to continue. (Click Cancel to discontinue the operation.) The Select Virtual Disk Type screen appears.

  4. Select the Type and Write Policy for the virtual disk.

Supported virtual disk types or RAID levels are available in the drop-down menu of the Type field.

Supported RAID levels are described in the Supported RAID Levels table near the beginning of this chapter.

Note When creating virtual disks in a disk group, use non-redundant RAID levels (such as concatenated or RAID 0) only when the disk group will not need hot-spare disk replacement. If a disk group contains at least one non-redundant virtual disk, any failed array disks in the disk group cannot be rebuilt with a hot-spare array disk.

The Write Policy toggles between Write Cache Enabled and Write Cache Disabled. When write cache is enabled, the controller returns a completion status to the host as soon as the cache receives the data. The target device receives the data at a more appropriate time. When write cache is disabled, the controller writes data to the target device before returning completion status to the host.

  1. When the virtual disk attributes are set appropriately, click Next to continue. (Click Back to return to the previous screen. Click Cancel to discontinue the operation.) The Select Disk screen appears.

  2. Select one or more spare disks for this virtual disk by checking the appropriate disk(s).

  3. When the spare disk or disks are selected, click Next to continue. (Click Back to return to the previous screen. Click Cancel to discontinue the operation.) The Completing the Add Virtual Disk Wizard screen appears.

  4. Click OK to continue.

  5. After the Add Virtual Disk process has completed, you MUST enable the partner controller to re-establish controller redundancy. See the Enable Partner command for more information.

Caution No rebuilds of redundant virtual disks will take place until after the Add Virtual Disk operation is completed and the partner is enabled.
  1. If you are using a SAN, see the SAN Administrator's Guide for instructions on how to assign the new virtual disk to a server, using the Dell OpenManage Storage Consolidation software.

After using the Add Virtual Disk command to increase the size of a virtual disk, you may note that the size of the virtual disk is larger than expected. This is because the virtual disk size is rounded up according to the RAID level and the number of array disks in the disk group. For more information on how the actual disk size is determined, see Virtual Disk Size.

Delete Disk Group

Use this function to remove the selected disk group from the array group.

Note Before you can delete a disk group, you must have deleted the virtual disks in the disk group.
  1. Right-click a disk group.

  2. Click Delete Disk Group. A warning/confirmation dialog box appears notifying the user that the selected disk group will be deleted. The user is asked to confirm this operation.

  3. Click Yes to continue. (Click No to exit the function.)

Note After deleting the last disk group, you must reset the configuration. See Reset Configuration in this chapter.

Disk Group Properties

The Properties command for a disk group gives the following information on the selected disk group:

Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Virtual Disk Commands

You can perform the following operations from a virtual disk's context menu:

To bring up a virtual disk's context menu, right-click the virtual disk object in the tree view. For more information why you would want to use virtual disks, see the section Create Virtual Disk in this chapter.

Change Policy

Use this function to change the write cache policy of a virtual disk. This setting will be used when the PowerVault 660F storage system is not in conservative cache mode.

  1. Right-click a virtual disk.

  2. Click Change Policy. The Write Policy dialog box appears.

Select either Write Cache Enabled or Write Cache Disabled. The Write Policy toggles between Write Cache Enabled and Write Cache Disabled. When write cache is enabled, the controller returns a completion status to the host as soon as the cache receives the data (improving write performance). The array disk receives the data at a more appropriate time. When write cache is disabled, the controller writes data to the array disk before returning completion status to the host.

  1. Click OK to make the change. (Click Cancel to discontinue the operation.)

Note If the controller is in conservative cache mode, the virtual disk will operate with write cache disabled regardless of the write cache policy setting.

Delete Virtual Disk

The Delete command for virtual disks is not available (menu option is dimmed) unless the following conditions are met:

Caution Deleting a virtual disk permanently deletes all information contained on that disk. It is strongly recommended that you first delete the volumes from the virtual disk (and offline the virtual disk from the server using Dell OpenManage Storage Consolidation if the PowerVault 660F is part of a Storage Area Network) before deleting the virtual disk.
Note This function is enabled only for the virtual disk that was created last. Because of hardware constraints, virtual disks must be deleted in the reverse order of their creation. In other words, you must delete the most recently created virtual disk first and continue to delete in reverse order.

Use this function to delete the virtual disk that was created last.

  1. Right-click the virtual disk that was created last.

  2. Click Delete. A warning/confirmation dialog box appears warning that all data on the selected virtual disk will be lost. The user is asked to confirm the operation.

  3. Click Yes to continue. (Click No to exit the function.) The virtual disk disappears from the left pane and the right pane in the Array Manager console if the array group is selected.

Initialize

Use this function to manually start a foreground initialization of a virtual disk. It is strongly recommended that you fully initialize a virtual disk before the virtual disk is accessed by a host computer operating system. Parity information may not be correct until the virtual disk is initialized.

The system will not be able to perform read and write operations on the virtual disk while it is being foreground initialized. You can also use background initialization, which enables the system to perform read and write operations during the initialization process. For more information on foreground and background initialization, see Understanding Virtual Disk Initialization.

Note It is possible to have foreground initializations ongoing for multiple virtual disks, but performing more than eight simultaneous virtual disk initializations at the same time can slow down the response time of commands between Array Manager and the PowerVault 660F array where the storage is being initialized. Array Manager will not allow more than eight simultaneous foreground initializations on a PowerVault 660F array.
Note Starting a foreground initialization will suspend any background initialization occurring on another virtual disk. The background initialization will continue once all foreground initializations are either completed or canceled.
Caution Performing a foreground initialization on a virtual disk will destroy all the data on that virtual disk.
  1. Right-click a virtual disk.

  2. Click Initialize. A warning/confirmation dialog box appears warning that all current data on the virtual disk will be lost and recommends that the user not perform any disk or volume operations on the virtual disk while the initialization is in progress.

  3. Click Yes to continue. (Click No to exit the function.) The initialization progress is indicated in the right pane. The virtual disk status indicates "Initializing" and the progress indicates the percent completed.

Cancel Initialize

Use this function to manually stop ALL foreground virtual disk initializations that are in progress for a single PowerVault 660F storage system.

  1. Right-click on a virtual disk that has an active foreground initialization.

  2. Click Cancel Initialize. A warning/dialog box appears asking you to confirm the operation.

  3. Click Yes to continue. (Click No to exit the function.)

Caution A redundant RAID configured virtual disk must have a complete initialization in order to set consistency on the disk. This can be done with either foreground or background initialization.

Background Initialize

Note The Background Initialize controller option is only available when using PowerVault 660F controller firmware 7.7 or later.

Use this command to initialize a virtual disk without interrupting the normal functioning of the virtual disk and to preserve the data on it. The Background Initialize command enables a server to use a virtual disk while the background initialization process is active. Background initialization can only be used with virtual disks configured as redundant RAID levels.

It is strongly recommended that you fully initialize a virtual disk before the virtual disk is accessed by a host computer operating system. Parity information may not be correct until the virtual disk is initialized. You can use the Background Initialize command to fully initialize the virtual disk.

For more information on virtual disk initialization, see Understanding Virtual Disk Initialization. This information includes a discussion of background initialization's impact on system performance and a list of operations that interrupt a background initialization.

To manually start a background initialization:

  1. Right-click on the virtual disk for which you want to start background initialization.

  2. Click Background Initialize. A confirmation dialog box is displayed.

  3. Click Yes to continue. (Click No to exit the function.) The background initialization process for that virtual disk will begin when the controller receives its next write request.

Note The Background Initialize menu will not be enabled if another virtual disk is already being initialized (in foreground or background). To queue up virtual disks for background initialization, you can set the Autostart Background Init option in the Advanced Controller Options. See Advanced Fibre Channel RAID Controller Options for more information on setting the Autostart Background Init option.

For information on canceling the background initialization, see Cancel Background Initialize.

Cancel Background Initialize

Note The Cancel Background Initialize controller option is only available when using PowerVault 660F controller firmware 7.7 or later.

Use this function to manually stop a background virtual disk initialization that is in progress.

  1. Right-click on the virtual disk that is being background initialized.

  2. Click Cancel Background Initialize. A warning/confirmation dialog box appears asking you to confirm the operation.

  3. Click Yes to continue. (Click No to exit the function.)

Caution A redundant RAID configured virtual disk must have a complete initialization in order to set consistency on the disk.

Check Consistency

Use this function to begin a consistency check. A consistency check verifies that mirror or parity information matches the stored data on the redundant RAID configured virtual disk (RAID-1, RAID-3, RAID-5, or RAID-0+1). If the parity block information is inconsistent with the data blocks, events will be generated in the event log showing this.

Note If a consistency check fails for a virtual disk, it will be necessary to initialize the virtual disk and restore the data from backup to correct the virtual disk.
Note Starting a check consistency will suspend any background initialization occurring on another virtual disk. The background initialization will continue once the check consistency is either completed or canceled.
  1. Right-click a virtual disk.

  2. Click Check Consistency. A warning/confirmation dialog box appears warning that other disk or volume operations on the corresponding disks not be performed while the consistency check is in progress. The user is asked to confirm this operation.

  3. Click Yes to continue. (Click No to exit the function.)

Cancel Check Consistency

Use this function to manually stop a consistency check that is in progress.

  1. Right-click a virtual disk.

  2. Click Cancel Check Consistency. A confirmation dialog box appears asking whether you want to cancel the consistency check.

  3. Click Yes to continue. (Click No to exit the function.)

Force Online

Use this function to force a failed virtual disk to online status. This command is needed to recover a failed virtual disk after one or more failed array disks are replaced.

Note If a failed redundant RAID configured virtual disk is forced online, you must initialize the virtual disk to establish consistency. Data previously on the virtual disk will be lost (since the virtual disk did suffer a failure).
  1. Right-click the offline virtual disk.

  2. Click Force Online. The status change is indicated in the right pane. All virtual disks in the disk group will have a status change from offline to online.

Virtual Disk Properties

The Properties command for a virtual disk gives the following information on the selected virtual disk:

Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Array Disk Commands

Array disks are the physical hard drives connected to the controller through the enclosure. The array disks are configured into disk groups to be configured as one or more virtual disks. You can perform the following operations from the Array Disk context menu:

To bring up an array disk's context menu, right-click the array disk object in the tree view.

Blink Disk

The Blink Disk command allows you to find an array disk within an enclosure by blinking one of the light-emitting diodes (LEDs) on the disk. You may want to use this command to locate an array disk that has failed.

Use the following steps to blink an array disk:

  1. Right-click an array disk.

  2. Click Blink Disk. The Locate Disk dialog box appears.

  3. Click Blink to activate the LED for the selected array disk. The LED on the hard-disk carrier may take 30 seconds to start blinking.

  4. Click Done when finished. The LED may continue blinking for another 30 seconds.

Rebuild

The Rebuild function starts a rebuild on a replace array disk for a degraded virtual disk. You can do only one rebuild at a time.

  1. Right-click an array disk.

  2. Click Rebuild.

A warning/confirmation dialog box appears recommending that you not perform any disk or volume operations on the corresponding disks while the rebuild is in progress, and asking whether you want to rebuild this array disk.

  1. Click Yes to continue. (Click No to exit the function.)

The status and progress are indicated in the right pane. The array disk status indicates "Rebuilding."

Note Starting a rebuild will suspend any background initialization occurring on another virtual disk. The background initialization will continue once the rebuild is either completed or canceled.

Cancel Rebuild

Use this function to manually stop a rebuild that is in progress.

  1. Right-click an array disk.

  2. Click Cancel Rebuild. A confirmation dialog box appears asking whether you want to cancel the array disk rebuild.

Click Yes to continue. (Click No to exit the function.)

Prepare to Remove

This command spins down the array disk to prepare it for removal from the enclosure. Only array disks that have a hardware failure or that have been brought offline can be prepared for removal.

Note Unused array disks that are not part of a virtual disk or set as hot spares are already spun down and can be removed at any time.
  1. Right-click an array disk.

  2. Click Prepare to Remove.

A confirmation dialog box appears asking whether you want to prepare this array disk for removal.

  1. Click Yes to continue. (Click No to exit the function.)

The array disk will spin down so that it can be removed.

Note After doing a Prepare to Remove operation on an array disk in a PV660F array, the array disk cannot be used for a rebuild. If you need to use this disk for a rebuild, then remove and reinsert the disk to automatically start the rebuild.

Make Global Hot Spare

Use this function to designate the selected array disk as a global hot spare disk. This function is also used to make a failed/offline array disk usable as a global hot spare.

  1. Right-click an array disk.

  2. Click Make Global Hot Spare. The array disk is labeled as a hot spare in the left pane. The information in the right pane is updated to indicate that the array disk status is Ready and the type is Spare Array Disk.

Unassign Global Hot Spare

Use this function to unassign the selected array disk as a global hot spare disk.

  1. Right-click an array disk.

  2. Click Unassign Global Hot Spare. The type change is indicated in the right pane. The array disk status indicates Ready and the type is Array Disk.

Make Offline

Use this function to force the selected disk to Offline status.

  1. Right-click an array disk.

  2. Click Make Offline. A warning/confirmation dialog box appears warning that loss of data may occur. The user is asked to confirm this operation.

  3. Click Yes to continue. (Click No to exit the function.) The status change is indicated in the right pane. The array disk status indicates a change from Online to Offline

Note Forcing an array disk that is part of a disk group offline may start a rebuild or may fail one or more virtual disks in the disk group.
Note An array disk that remains in offline state can be brought back online. To do this, you must make it a global hot spare. If desired, it can later be unassigned as a hot spare and used as part of a disk group.

Array Disk Properties

The Properties command for an array disk gives the following information on the selected array disk:

Disk Properties
Disk
Size
Status
Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Fibre Channel RAID Controller Commands

You can perform the following controller operations, which gives you the ability to configure and manage your system:

To bring up a controller's context menu, right-click the controller object in the tree view.

Fibre Channel RAID Controller Options

Each Dell PowerVault 660F Storage System is shipped from the factory with initial settings that have been found to work well in a majority of applications and environments. These settings are listed as the controller options and vary depending on product and user requirements. You can customize controller options and features to meet the specific needs of your operating environment. The Controller Options dialog box has the following tabs:

You can also revert any settings you make to the default factory options.

Revert to Factory Controller Options

Use the revert function to return to the Dell PowerVault 660F storage system factory default values at any time from any controller option page.

To Revert to Factory Default Values
  1. Right-click a controller.

  2. Click Controller Options. The Controller Options multi-tabbed dialog box appears with the Advanced tab open.

  3. Click Revert. The Revert to Factory Defaults dialog box appears.

  4. Select either Current Page Only or All Controller Options.

  5. Current Page Only returns the controller options on this page only to the factory default values.

All Controller Options returns all controller options to the factory default values.

  1. Click OK to make the changes. (Click Cancel to discontinue the operation.)

  2. A controller reset is required when making certain controller option changes. Controller options requiring a controller reset are indicated with a fly-by dialog when the mouse cursor moves over the controller option. A controller reset is recommended after making any changes to the controller configuration. If a dialog box does NOT appear with the warning that a controller reset will occur, refer to the Reset command for controller reset instructions.

Advanced Fibre Channel RAID Controller Options

To make changes to the Advanced controller options settings:

  1. Right-click a controller.

  2. Click Controller Options.

  3. Click the Advanced tab to continue. The Advanced tab opens.

Note Checking a specific option activates that option, either enabling or disabling the option as stated in the dialog box. No check indicates that the option is disabled.
  1. Make changes to the following Advanced controller options as required by your operating environment:

Customizations

Internals

  1. When the Advanced controller options are set appropriately, click OK to make the changes. (Click Revert to revert controller options to factory default values. Click Cancel to discontinue the operation.)

Expert Fibre Channel RAID Controller Options

To make changes to the Expert Fibre Channel RAID controller options:

  1. Right-click a controller.

  2. Click Controller Options.

  3. Click the Expert tab to continue. The Expert window opens.

Note Checking a specific option either enables or disables the option as stated in the dialog box. No check indicates that the option is disabled.
  1. Make changes to the following Expert controller options as required by your operating environment:

  2. When the Expert controller options are set appropriately, click OK to make the changes. (Click Revert to revert controller options to factory default values. Click Cancel to discontinue the operation.)

Fibre Channel RAID Controller Options

To make changes to the Fibre Channel RAID controller options:

  1. Right-click a controller.

  2. Click Controller Options.

  3. Click the Fibre tab to continue. The Fibre tab opens.

Note Checking a specific option either enables or disables the option as stated in the dialog box. No check indicates that the option is not enabled.
  1. Make changes to the following Fibre controller options as required by your product and configuration:

  2. When the Fibre controller options are set appropriately, click OK to make the changes. (Click Revert to revert controller options to factory default values. Click Cancel to discontinue the operation.)

  3. A controller reset is required when making some controller option changes. Controller options requiring a controller reset are indicated with a pop-up window when the mouse cursor moves over the controller option. A controller reset is recommended after making any changes to the controller configuration. If a dialog box does NOT appear warning that a controller reset will occur, refer to the Reset command for the controller reset instructions.

Add Enclosure

The Add Enclosure command allows users to add device enclosures (one or more) to a configured system while the system continues to operate. After the enclosure or enclosures have been added to the system, the Add Enclosure command initiates the SES monitoring process for the added enclosure(s). The user can configure the additional disk drive capacity without rebooting the PowerVault 660F storage system through Array Manager.

To Add Enclosures
  1. Attach and cable the new enclosure(s) to the system while the new enclosure(s) are powered off. Be sure to check for and resolve any enclosure shelf ID conflicts. Refer to the appropriate documentation for enclosure installation.

  2. Power on the new enclosure(s).

  3. Wait for all the drives to complete the spin-up process.

  4. Right-click the corresponding controller object in the Array Manager console's left pane.

  5. Select Add Enclosure.

  6. Right-click the PV660 SubSystem object and select Rescan.

Download

The Download command allows you to download controller firmware or SES firmware. To use the command, right-click the controller object. Then select the Download command from the context menu that comes up. A submenu appears for selecting either of the two download options. For details, see:

Note Upgrading from PowerVault 660F Storage System firmware version 7.51 to version 7.7 or higher will change the controller's World Wide Name (WWN). When the WWN changes, you will not be able to see the storage system with Array Manager. Resolving this problem can include updating pathing of the FC HBA, as well as FC switch zoning configuration if zoning is being performed by WWN. See the documentation accompanying the new controller firmware, and the latest SAN or PowerVault 660F documentation that came with your system or that is available from the Dell support document library at http://support.dell.com for information on editing the FC switch zone table and resolving problems associated with a new WWN.

Fibre Channel RAID Controller Firmware

Note Before downloading firmware, be sure to suspend all I/O (including Virtual Disk initializations, check consistency, rebuilds, Expand Capacity, and Add Virtual Disk) to the PowerVault 660F storage system.
  1. Select Controller Firmware.

The Download Firmware dialog box appears. The dialog box provides a standard browser for locating the appropriate firmware image file.

  1. Click Browse to locate the file and enter the path and filename. Information about the selected file displays.

  2. Verify that the selected file is correct. If a valid file is not selected, the command is not executed.

  3. Click Apply to begin the download process. (Click Cancel to discontinue the operation.)

Note If downloading to a redundant controller system, both controllers will receive the firmware simultaneously.

If downloading controller firmware version 7.7 or later onto a storage system running version 7.51, you will have to manually power down and back up the storage system before the new firmware will take affect. Additional steps to configure the SAN for the newly downloaded storage system will be required -- see the Note above for more information.

SES Firmware

Use this function to upgrade enclosure SES firmware as new versions become available. Array Manager allows you to download new SES firmware to the SES device. You will be able to download to all SES devices associated with the PowerVault 660F array. The SES Download wizard guides you through the process.

Note When downloading SES firmware, make sure that the SES firmware for all enclosures attached to a PV660F storage subsystem are at the same level.
  1. Select SES Firmware.

  2. Read the welcome screen and click Next to continue. (Click Cancel to discontinue the operation.)

The Select Enclosures screen appears.

  1. Select the enclosures for which you want to download SES firmware. Click Next to continue. (Click Back to return to the previous screen. Click Cancel to discontinue the operation.)

  2. Click Browse to locate the file and enter the path and filename.

  3. Verify that the selected file is correct. If the correct file is not selected, the command is not executed.

  4. The Completing the SES Download Wizard screen appears. Click Next to continue. (Click Back to return to the previous screen. Click Cancel to discontinue the operation.)

  5. Click Finish to continue. (Click Back to return to the previous screen. Click Cancel to discontinue the operation.)

While the SES download is ongoing, the SES Download Wizard will show the progress of the download. If you open another window over the Wizard window, it will temporary erase the existing progress information. Once the Wizard window is updated with new information, all existing progress information will be redisplayed.

Note After successfully downloading the SES firmware, you may receive a warning stating that the firmware is mismatched. Rescan the PV660F subsystem to resolve this warning.

Disable Partner

Use this function to hold the partner controller in reset and initiate the failover process. If you are planning to use the Expand Capacity or Add Virtual Disk commands, those commands are not available unless you use this command first to hold the partner controller in reset and transfer control to a single controller. After the Expand Capacity or Add Virtual Disk command is completed, you need to use the Enable Partner command to return to a redundant controller configuration with both controllers operating.

Note Disabling the partner controller forces all I/O to the subsystem to go through the surviving controller. Any servers connected to the Fibre Channel fabric may experience an HBA failover (depending on the fabric configuration) in order to redirect I/O to the surviving controller.

To use the Disable Partner command:

  1. Right-click a controller.

  2. Click Disable Partner. This command is invoked immediately; no warning or confirmation screen appears. The partner controller is held in reset. The surviving controller operates as a failed-over redundant controller.

Enable Partner

Use this function to return the partner controller to full functionality. Enable the partner controller following an Expand Capacity or Add Virtual Disk operation to return the system to a redundant controller configuration.

Note Enabling the partner controller allows I/O to be processed by both controllers. For a SAN environment, manual HBA failovers may be necessary to have servers use the newly enabled controller.

To use the Enable Partner command:

  1. Right-click the active controller.

  2. Click Enable Partner. This command is invoked immediately; no warning or confirmation screen appears. The failback process begins, and the partner controller resumes full functionality.

Note If a virtual disk is being initialized in the background, the Enable Partner function will fail. You must either wait until background initialization is complete or canceled before successfully performing an Enable Partner.
Note If after performing the enable partner command, the controller object Properties command only shows one controller, you will have to perform a rescan on the PV660F SubSystem object in the Array Manager tree view to have Array Manager recognize both controllers. This most often occurs when Array Manager is started while the storage system had its partner controller disabled.

Reset

Use this function to reboot the controllers in the storage system. After creating a new configuration or making changes to controller options, a controller reset is recommended.

  1. Right-click a controller.

  2. Click Reset. A warning/confirmation dialog box appears notifying the user that a controller reset will take 30 seconds or longer. The user is asked to confirm this operation.

  3. Click Yes to continue. (Click No to exit the function.) A warm power cycle occurs immediately on the controllers.

Note A reset can be done only when the following two conditions both exist: 1) There is no I/O to or from the controllers, and 2) no initializations, rebuilds, check consistency, Expand Capacity, Add Virtual Disk are in progress.

Disable BBU

Use this feature to prepare the storage system for power down. This procedure forces the controller into conservative cache mode, flushes the cache, and electronically disconnects the battery.

  1. Right-click a controller.

  2. Click Disable BBU. A warning/confirmation dialog box appears notifying you that the controller will be prepared for removal. You are asked to confirm this operation.

  3. Click Yes to continue. (Click No to exit the function.)

Enable BBU

Use this function to return the controller to normal cache operation. This enables the BBU to protect the write-cache. If the array is in an optimal state, this operation sets the controller to normal cache mode.

  1. Right-click on a controller object.

  2. Click Enable BBU. A warning/confirmation dialog box appears notifying the user that the controller will return to normal operation. The user is asked to confirm this operation.

  3. Click Yes to continue. (Click No to exit the function.)

C0 Battery and C1 Battery

The C0 Battery represents the battery for the C0 controller (right side on the rear view of the storage system), and the C1 Battery represents the battery for the C1 controller (left side on the rear view).

Use these menu items to manage the following battery functions:

Recondition

Certain conditions make it beneficial for the BBU battery to be reconditioned before it can be used. If you are installing a new controller or replace the battery, then the battery should be reconditioned. This will fully validate the maximum battery charge possibly.

A full battery recondition cycle consists of fully discharging and recharging the battery. The recondition cycle must start with a fully charged battery. When the battery is first connected, it will run a calibration phase which will identify the battery charge.

The recondition cycle must be initiated manually and must complete without an interruption of power. In addition, the operator must not interrupt the cycle while it is in process. If the cycle is interrupted for any reason, the batteries must be recharged and the recondition process must be restarted.

Note During the reconditioning, write back cache mode will be disabled as the battery charge falls below the battery threshold. This may slow performance of the storage system. Therefore, schedule this operation accordingly.

To recondition a battery on a PV660F controller:

  1. Right-click a controller.

  2. Click C0 Battery or C1 Battery for the battery associated with the selected controller.

  3. Click Recondition. The recondition cycle begins immediately and must not be interrupted.

For more information about the BBU, see the following:

Cancel Recondition

This section applies to the PV660F storage system

To cancel a battery recondition on a PV660F controller:

  1. Right-click a controller.

  2. Click C0 Battery or C1 Battery for the battery associated with the selected controller.

  3. Click Cancel Recondition. The recondition cycle is cancelled immediately.


Change Low Threshold

Use this function to modify the power level used to trigger an alarm when the battery power level drops below the set value. Once the battery's power level falls below this threshold, the controllers will enter conservative cache mode (i.e., write cache disabled).

  1. Right-click a controller.

  2. Click C0 Battery or C1 Battery for the battery associated with the selected controller.

  3. Click Change Low Threshold. The Change BBU Low Threshold dialog box appears. The current value in minutes is shown.

  4. Enter the new value. Click OK to make the changes. (Click Cancel to discontinue the operation.)

Battery Properties

This command includes the following battery properties information:

General Characteristics
Power
Attributes

This is an informational field describing the current attribute(s), for example, Fast Charge is not active or Recondition is not active.

States

This field provides a status icon and information about the current state of the battery. A blue check indicates good status, and a red X indicates a problem or poor status.

Status

This field displays the current status of the battery. Possible values are:

Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Fibre Channel RAID Controller Properties

This command displays the following categories of properties for one or both controllers in the Dell PowerVault 660F storage system:

General Fibre Channel RAID Controller Characteristics
Dual Controller Status
Host Connection Information
Port
Status
Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Subsystem Commands

The PV660F SubSystem folder object consists of physical and logical arrays. The physical arrays include objects for the RAID controllers, enclosures, disks, fans, power supplies, and temperature probes. The logical arrays include objects for the virtual disks on the storage system. The logical arrays are created, monitored, and maintained by Array Manager.

Right-clicking a PV660F SubSystem folder object in the tree view brings up a context menu with subsystem commands. Similarly, right-clicking a physical or logical array object also brings up a context menu.

You can perform the following operations from the Subsystem context menu:

The physical array object context menu allows you to:

The logical array object context menu allows you to:

Note Commands related to the enclosure, fans, power supply, and enclosure temperature are covered in the next major section, Enclosure Management Overview and Commands.

Rescan Subsystem

You can scan for new PowerVault 660F Storage Systems or hardware configuration changes to existing storage systems by using the Rescan function.

  1. Right-click a subsystem.

  2. Click Rescan. This command is invoked immediately; no warning or confirmation screen appears. The added components appear in the left pane.

Subsystem Properties

The Properties command for the PV660F SubSystem object provides the name, vendor, and status of the subsystem. Possible values for status are:

Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Physical Array Properties

The Physical Array Properties dialog box displays the name, vendor, and status of the physical array. Possible values of the status field are:

Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Logical Array Properties

The Logical Array Properties dialog box displays the name and status of the logical array. Possible values of the status field are:

Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Enclosure Management Overview and Commands

Dell PowerVault 224F enclosures have enclosure management capability. This section describes how enclosure management works and then details the specific enclosure management commands. The specific topics in the section are:

Enclosure Management Overview

Array Manager allows you to view all the external Fibre Channel system probes within the same integrated Array Manager console. You are notified of any enclosure status changes while the console is open, and logged events appear in the Events tab as well as in the Windows Event Log.

The Fibre Channel subsystem of Array Manager provides direct support for the display of instrumentation of Fibre Channel enclosures. No other software is required to be installed.

The storage objects associated with enclosures and enclosure management are:

Enclosures

When you expand the PV660F SubSystem storage object in the tree view, you will see one or more controllers attached to the subsystem along with one or more enclosures that are attached to each controller. As shown in the sample screen below, an enclosure has Disks, Fans, Power Supplies and Temperature Probes storage objects associated with it.

Enclosure Management Storage Objects

In the above screen, the enclosure is identified as "Enclosure 0:1." The zero refers to the number of the controller the enclosure is attached to. The "1" means that it is the first enclosure attached to that controller. If there were a second and a third enclosure attached to Controller 0, they would be called "Enclosure 0:2" and "Enclosure 0:3," respectively. If you right-click an Enclosure storage object, you will get a context menu with enclosure commands. For details, see the section Enclosure Commands in this chapter.

The subordinate Enclosure storage objects—Disks, Fans, Power Supplies, and Temperature Probes—are described in the sections that follow.

Disks

The enclosure's array disks are displayed under the Disks folder object. When the Disks folder object is highlighted in the left-pane tree view, the right-pane panel of the console window lists these disks along with their operating status and other properties. If you right-click on one of the subordinate array disks object of the Disks folder object, the Array Disks context menu will come up. See Array Disk Commands for details on these commands.

Fans

The enclosure's fans are displayed under the Fans folder object. When the Fans folder object is highlighted in the left-pane tree view, the right-pane panel of the console window lists the enclosure's fans along with their operating status and other properties. If you right-click on one of the Fans object, a context menu comes up with a Fan Properties command.

Power Supplies

The power supplies that are installed in the enclosure are displayed under the Power Supplies folder object. When the Power Supplies folder object is highlighted in the left-pane tree view, the right-pane panel of the console window lists the enclosure's power supplies along with their operating status and other properties. If you right-click on any of the Power Supplies object, a context menu comes up with a Power Supply Properties command.

Temperature Probes

The temperature probes that are installed in the enclosure are displayed under the Temperature Probes folder object. When the Temperature Probes folder object is highlighted in the left-pane view, all of the enclosure's temperature probes are displayed along with their operating status and other properties. The categories are Status, Current Value, Minimum Warning Limit, Maximum Warning Limit, Minimum Error Limit, Maximum Error Limit, and Unit of Measurement. The unit of measurement is degrees Celsius. If you right-click on any of the Temperature Probes objects, a context menu comes up with two commands, Temperature Properties and Set Thresholds for Temperature. The Set Thresholds for Temperature command displays the enclosure temperature and the thresholds for critical and warning temperature events. It allows you to set the temperature threshold for warning temperature levels.

Note Only the warning threshold of the LS Modules (SES) temperature probes can be set, and setting the warning threshold of either LS Module will result in the warning thresholds of both LS Modules to be set to the new value. The warning thresholds of the power supply temperature probes are set to a fixed value.

LS Modules (SES)

LS (or SES) modules are cards installed in slots at the front of the enclosure. Each LS module has an SES processor that monitors environmental functions. LS modules also have a Loop Redundancy Circuit (LRC) function, which maintains the viability of the Fibre Channel loop. LS modules are not displayed in the Array manager tree view.

Note When downloading firmware to the LS or SES module, make sure the firmware for all modules and all enclosures attached to a PV660F storage subsystem are at the same level. In addition, it is recommended that the firmware for all enclosures in a SAN be at the same level.

For more information, see SES Firmware.

Enclosure Commands

This section describes the commands associated with the Enclosure storage object and its subordinate storage objects. Right-clicking on the enclosure object in the tree view of an Dell PowerVault 224F array disk enclosure brings up a context menu with enclosure commands. Under each enclosure are objects in the tree view for fans, power supplies, and temperature. Right-clicking each of these subordinate objects brings up a context menu as well.

The Enclosure context menu commands are:

The context menu commands for fans, power supplies, and temperature are:

Alarm Enabled

Use this function to enable the alarm when the enclosure exceeds a warning threshold for temperature; when a disk drive, power supply, fan, or controller fails; and during the controller boot-up process. Once the alarm is enabled, the audible alarm sounds whenever the fault LED lights. To invoke the command, right-click the enclosure and select Alarm Enabled from the context menu that appears.

Alarm Disabled

Use this function to disable the alarm. To invoke the command, right-click the enclosure and select Alarm Disabled from the context menu that appears.

Asset Settings

The Asset Settings command brings up a dialog box that allows you to enter or change the asset tag and asset name for the array disk enclosure. Each enclosure of the PowerVault 660F Storage System can have its own asset settings. To perform the command:

  1. Right-click on an enclosure object.

  2. Click Asset Settings.

The Asset Information dialog box appears with two entry boxes, Asset Tag and Asset Name.

  1. If the values shown need to be changed, enter a new value for the asset tag and a new asset name.

The asset tag for the selected enclosure will be added to the controller name in the object tree -- for example, Controller 1 (Enclos53), where "Enclos53" is the asset tag for the first enclosure attached to Controller 1. The first enclosure attached to a controller is the enclosure in which the pair of redundant controllers are installed. The asset tag is also used to identify the PowerVault 660F array in the Dell OpenManage Storage Consolidation software (if the array is used in a Storage Area Network (SAN).

Note The asset tag is limited to 10 characters, and the asset name is limited to 32 characters.
  1. Click Set to make the changes. Click Cancel to exit the function without accepting the changes.

Note If you have recently added an enclosure to the PV660F storage system, then the changes you make to the asset tag may not be applied even after doing a rescan. If this is the case, first rescan the controller and then change the asset tag.

Enclosure Properties

Use this function to view the following information about the selected enclosure:

Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Fan Properties

Use this command to view the following fan properties:

Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Power Supply Properties

Use this command to view the following power supply properties:

Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

Set Thresholds for Temperature

Note This command can only be performed on the LS Modules (SES) temperature probes.

This command displays the enclosure temperature and the thresholds for critical and warning temperature levels. The warning thresholds can be changed. All values are expressed in degrees Celsius. To perform the command:

  1. Right-click on a LS module temperature probe object in the tree view.

  2. Select Set Thresholds for Temperature from the context menu that appears.

A dialog box comes up that displays the following temperature-related information:

High or 55 degrees Celsius: This value is the high critical limit. If this value is exceeded, the system sound the audible alarm (if enabled).

Low or 1 degree Celsius: This value is the low critical limit. If temperature drops below this value, the system will sound the audible alarm (if enabled).

High: When this value is exceeded, a warning alarm sounds, if the alarm is turned on. The upper limit for the high warning threshold is 35 degrees Celsius.

Low: When the temperature drops below this value, a warning alarm sounds, if the alarm is turned on. The lower limit is 20 degrees Celsius.

  1. Make any necessary changes to the Warning Threshold values.

Note Thresholds are set based on room temperature expectations. The temperatures reported by the subsystem are actual values. The subsystem automatically adjusts the entered thresholds to account for internal temperature limitations.
  1. Click OK to make the changes. Click Cancel to discontinue the operation.

Temperature Properties

Use this command to view the following temperature-related properties:

Note All values are expressed in degrees Celsius.
Note If the status value is anything other than Ready, a red X appears to the left of the status to indicate a situation that requires attention.

RAID Policies

Today's storage management tools used for configuring and managing storage subsystems require the system administrator to have a great deal of knowledge about RAID technology. To simplify storage management, the PV660F storage subsystem enables you to use RAID Policies, which are automated RAID configuration methods that are application-based.

Overview

RAID Policies provide the following functions:

If RAID-based server hardware is used to set up an application server (Exchange, Notes, SQL, or Oracle), then Array Manager's RAID Policies make this task simple.

Using Standard RAID Policies

Most common mail server and database server applications require a specialized storage configuration. Some of the application server software components require a highly redundant storage configuration; others require a high-performance storage configuration. Array Manager standard RAID Policies are designed to meet the storage configuration needs of the following software:

To Use a Standard RAID Policy
  1. Right-click an array group and select Apply RAID Policy to launch the RAID Policy wizard.

  2. Read the welcome screen. Click Next to display the Select RAID Policy window or cancel the operation by clicking Cancel.

  3. Select a RAID Policy by highlighting an option under Mail Server Policies, Database Server Policies, or Generic Policies.

  4. Review the storage configuration for the selected RAID Policy. You can modify the policy attributes in the right pane of the Select RAID Policy window or use the defaults.

When ready click Next to display the Select Disks window. The Select Disks window displays the selected disks.

  1. Modify the disk selection as necessary by using the Add Disk, Remove Disk, or Remove All buttons. Click Next to continue.

  2. Click Finish to execute the selected RAID Policy.

Since processing a RAID Policy involves several steps, such as in the example of creating virtual disks, it might take several minutes to complete the task. The RAID Policy wizard automatically creates the appropriate virtual disks.

Using Custom RAID Policies

To Create a Custom RAID Policy
  1. Right-click an array group and select Edit RAID Policy to launch the RAID Policy wizard.

  2. Click the New Policy button to create a new policy.

  3. Enter a name for the custom RAID policy in the Policy Name field. Use the Add Disk and Remove Disk buttons to add and remove disks. Click the OK button.

  4. After creating a custom RAID Policy, use Apply RAID Policy to execute the policy.

To Modify a Custom RAID Policy
  1. Right-click an array group and select Edit RAID Policy to launch the RAID Policy wizard.

  2. Click the Modify Policy button to modify an existing custom policy.

To Delete a Custom RAID Policy
  1. Right-click an array group and select Edit RAID Policy to launch the RAID Policy wizard.

  2. Click the Delete button to delete an existing custom policy.


NetWare Support for the PowerVault 660F

After installation, PowerVault 660F management by NetWare is disabled by default. You can enable NetWare support for a PowerVault 660F from a Windows system by using the Array Manager Utilities. When using the Array Manager Utilities, you will select the NetWare tab and then enable the PV660F component.

For detailed information on enabling the PV660F component for NetWare, see Adding and Removing Fibre Channel RAID and Enclosure Management.

For information on SAN support for NetWare, see the Dell PowerVault Systems Storage Area Network (SAN) documentation.


How the Battery Backup Unit Works

The battery backup unit (BBU) monitors and charges the cache backup battery for the PowerVault 660F. In order for the BBU to properly monitor and charge the cache backup battery, it first automatically performs a battery calibration and then Array Manager logs an event stating that a BBU recondition is suggested. The steps in both of these processes are identical except that the calibration process takes place automatically whereas you start the recondition process manually. Both the calibration and recondition processes consist of a battery discharge followed by a battery charge.

The BBU was designed to compare the low/high battery charges between the calibration and recondition cycles for accurate reporting. It performs the calibration cycle automatically. Dell OpenManage Array Manager logs an event stating that a BBU recondition is suggested. Upon completion of the recondition cycle, the BBU compares the capacity values for the battery. If the capacity values are within a nominal range, the recondition process is complete. However, if the capacity values exceed this nominal range, Array Manager will log another event message stating that a BBU recondition is suggested so that it can determine if the battery is operating properly.

The calibration cycle allows the BBU to determine the low and current capacity values for the battery and is required for proper operation of the write cache. The recondition cycle allows for more accurate capacity value reporting and is not required for normal write cache operation, but is recommended to verify battery capacity.

These are the events that require a battery calibration and subsequent recondition:

Note Removing and reinserting a fan pack while the power is turned off is equivalent to installing a new battery.

If you power off or reset the PowerVault 660F during a calibration, the process restarts automatically.

If you power off or reset during a recondition, Array Manager displays an alert in the Events tab that lets you know the recondition has failed. Next, Array Manager logs an event stating that a BBU recondition is suggested.

It is recommended that you perform both a calibration and recondition because the BBU uses these two sets of low/high battery charge values to accurately determine the battery's actual charge status. Until then, the BBU relies on the battery manufacturer's specifications, which may give inaccurate information about the actual battery installed in the storage subsystem.

Array Manager indicates the maximum capacity value based on battery manufacturer specifications. After both the calibration and reconditioning cycles are complete, Array Manager uses this information to show actual capacity.

For more information, see the following sections:

Battery Calibration

Typically, the battery shipped with a new PowerVault 660F Storage System will not be charged to 100 percent. In other words, the first battery discharge phase during calibration could easily take far less time than the maximum 19 hours. You can expect the fast charge time to take six hours.

It is recommended that you allow sufficient time when you first start the PowerVault 660F during a storage area network (SAN) site installation. Do not interrupt the first two phases of the PowerVault 660F BBU calibration cycle (the battery discharge and fast battery charge). These two phases combined require no interruption for seven to 25 hours. If you must interrupt the process, the calibration cycle will restart from the beginning, but you have not caused damage to the device. Interruptions increase the time needed to get the PowerVault 660F Storage System's batteries running at an optimum 100 percent charge.

Note Pulling the controller or fan pack during the calibration cycle interrupts that cycle. You will know when the fast charge process finishes because Array Manager will display a message asking you to recondition the battery.

For related information, see the following sections:

Battery Recondition

Keep in mind, the BBU Recondition is Suggested message is informational and is not an error message.

You can perform the recondition cycle during your next scheduled maintenance. After you do this, Array Manager will be able to give you a calculated maximum power value based on information from both the calibration and recondition cycles. However, it is not a requirement for you to perform the reconditioning immediately after the calibration.

Dell OpenManage Array Manager will notify you when it is time to perform another recondition. It does this after the battery level drops 30 times below an 85 percent charge. When you receive this message, you can plan another recondition at your next scheduled maintenance. Reconditioning is not required based on elapsed time. Rather, it is based on the number of times the battery discharges below 85% as described above.

For related information, see the following sections:

Indicators for Battery Calibration and Recondition

This section lists the Array Manager indicators that you can observe during the calibration and reconditioning cycles.

1 - Calibration Battery Discharge Phase
2 - Calibration Battery Fast Charge Phase
3 - Recondition Battery Discharge Phase
4 - Recondition Battery Fast Charge Phase

For related information, see the following sections:


Back to Contents Page